ABSTRACT

MEASURMENT OF DISCOMFORT
GLARE INDICES BY USING A CCD
CAMERA


This report describes an investigation into measurement of direct discomfort glare indices by using a CCD camera, frame grabber board and a computer.

Assessment of glare indices with standard spot luminance meter is time-consuming and stressful, since they allow only one reading at a time. This report is concerned with development of a new measurement system. Calibration and configuration of the hardware and software of the system will be discussed.

The measurement system essentially comprises of a CCD camera with lens and correction filters for acquiring luminance information from the scene. Personal Computer with image capture board is use for storing and analyzing of the data. The block diagram and components of the glare measurement system is given on the figure below.

The analogue signal from the camera is captured and converted to an 8 bit digital image by the image capture board. The digital data obtained is interpreted by image analysis algorithms to give luminance values and hens the glare rating of the captured scene. MATLAB(R) image processing toolbox was used to write the image analysis source code.